¿­·¢k8¹ú¼ÊÊ×Ò³µÇ¼£¬¿­·¢ÊÖ»ú¹ÙÍø

AisaIBIS¸ß¹âÆ×Ò£¸Ð¿Õ¼ä³ÉÏñϵͳ

¼òÒªÃèÊö£ºAisaIBIS¸ß¹âÆ×Ò£¸Ð¿Õ¼ä³ÉÏñϵͳ1.Spectral Range¹âÆ×·¶Î§: 670-780 nm 2.Spectral resolution£º0.11nm3.F/#: F/1.74.FOV,focusing range: 32.3°degrees,0.5m to infinity5.Detector ̽²âÆ÷: sCMOS,snapshot mode ¸ßÁéÃô¶È

  • ³§ÉÌÐÔÖÊ£º´úÀíÉÌ
  • ¸üÐÂʱ¼ä£º2024-10-24
  • ·Ã  ÎÊ  Á¿£º 1867

Ïêϸ½éÉÜ

AisaIBIS¸ß¹âÆ×Ò£¸Ð¿Õ¼ä³ÉÏñϵͳ

¹âÆ×Ó°ÏñÖ÷Ì壺

1.  Spectral Range¹âÆ×·¶Î§: 670-780 nm

2.  Spectral resolution£º0.11nm

3.  F/#: F/1.7

4.  FOV,focusing range: 32.3°degrees,0.5m to infinity

5.  Detector ̽²âÆ÷: sCMOS,snapshot mode ¸ßÁéÃô¶È

6.  Spatial pixels: 768

7.  Spectral bands: 1000

8.  Smile/Keystone: < 0.3 pixels

9.  Detector cooling̽²âÆ÷ÖÆÀ䷽ʽ:Peltier

10. Optics temperature stabilization: Yes

11. Camera output³ÉÏñ½Ó¿Ú: 16bit CL cameralink

12. Signal-to-noise ratioÐÅÔë±È£º680:1

13. ÅäÌײɼ¯¿¨¼°ÏßÀÂData cable: Length 5meters

14. Frame grabber: BitFlow Karbon CL-4

15. Camera control: USB/RS232

16. Framer rate:100Hz

17. Æعâʱ¼ä¸ù¾ÝËٶȸıä×Ô¶¯µ÷Õû

18. ¹¦ºÄ£ºÒ»°ãÊÇ135W£¬Max 200W

19. µçѹ£º18-36V

20. Ö÷Ìå³ß´ç£º588*227*160mm£»µçÔ´¼°DPU³ß´ç£º300*190*130mm

21. ÖØÁ¿£ºÖ÷Ìå14.2kg ,µçÔ´¼°DPUµÄÖØÁ¿£º5kg

22. Electro-mechanical shutter: Res

23. Shutter: Electro-mechanical shutter for dark image acquisition

24. Storage´æ´¢Î¶È£º-20°C - +50 °C

25.pectralDAQ support: Res

26.Accessories: Radiometric and geometric calibration, white calibration tile

 

AisaIBIS¸ß¹âÆ×Ò£¸Ð¿Õ¼ä³ÉÏñϵͳ

DPU with RSCube software

1.  Compact DPU with graphical user interface

2.  Wide 18-36 V DC operating voltage. ±È½Ï¿íµÄ18-36VµÄÖ±Á÷¹¤×÷µçѹ

3.  High performance data acquisition unit, capable of continuous data acquisition and storage without lost frames at data rate of 75 MB/s. ¸ßÐÔÄÜÊý¾Ý²É¼¯µ¥Ôª£¬Äܹ»Á¬ÐøµÄÊý¾Ý²É¼¯ºÍ´æ´¢£¬¶ø²»¶ªÊ§Ö¡µÄÊý¾ÝËÙÂÊΪ75 Mb / s¡£

4.   Solid state system disk.  ¸ßÎȶ¨ÐÔ¹Ì̬ӲÅÌ

5.   2 solid state hot-swap disks for data collection. Capacity altogether 512 GB, sufficient for 4 hours continuous acquisition£»2¸ö¹Ì̬ӲÅ̽»ÌæÊý¾Ý²É¼¯£¬ÈÝÁ¿512GB¡£¿ÉÒÔ4СʱÁ¬Ðø²É¼¯

6.  Automatic positioning and image data stream synchronizing solution. The solution provides synchronization between image and positioning data every second. Synchronization is referenced to the 1PPS pulse from the GNSS/IMU sensor and gives timing for the image frames with resolution of one millisecond. ×Ô¶¯¶¨Î»ºÍͼÏñÊý¾ÝÁ÷ͬ²½µÄ½â¾ö·½°¸

7.  SPECIM RSCube software is readily installed for controlling the sensor and data acquisition and storing synchronized positioning and image data

RSCubeÈí¼þ.°üº¬Í¼Ïñ²É¼¯£¬Í¬Ê±´æ´¢Í¬²½¶¨Î»¼°Í¼ÏñÊý¾Ý

8.  The image data format is ENVI compatible bil16 raw binary format with ASCII header file. ͼÏñÊý¾ÝÊÇÊʺÏENVIÅäÌ×ʹÓõÄ16λµÄԭʼÊý¾Ý¸ñʽ

9.  Gigabit LAN and USB 3.0 connections for fast data extraction.

¿ÉÒÔʵÏÖǧÕ×Íø¼°USB3.0µÄÊý¾Ý¿ìËÙ»ñÈ¡

 

AisaIBIS¸ß¹âÆ×Ò£¸Ð¿Õ¼ä³ÉÏñϵͳ

Cable set for AisaIBIS

Includes all cables required for an operational AisaIBIS system

 

AisaIBIS¸ß¹âÆ×Ò£¸Ð¿Õ¼ä³ÉÏñϵͳ

¹âÆ×ͼÏñÊý¾Ý´¦Àíµ¥ÔªÏµÍ³ Isuzu-V2.0

1.  Display interface: ¿ÉÏÔʾ¹âÆ×ÇúÏß¼°¹âÆ×ͼÏñ

2.  Recording control of spectral images to hard disk. Data format is compatible to ENVI processing software. ÓëENVIÈí¼þÅäºÏ·½±ã

3.   White and dark corrections. ºÚ°×УÕý

4.  Stepping motor control  »úеƽ̨¼°Ðýתƽ̨µÄ¿ØÖÆ

5.  Spectral Image Analyzer ¹âÆ×ͼÏñ·ÖÎö

6.  Spectral reflectance calculation¹âÆ×·´ÉäÂʼÆËã

7.  Spectral angle mapping(SAM)¹âÆ×Æ¥Åä½Ç¶ÈÌîͼ¹¦ÄÜ

8.  Cut ROI(Range of interest)µµ°¸ÇиÄÜ

9.  Color/ Mono image display²Ê/µ¥É«Í¼ÏñÏÔʾ

10. Single Spectral image & 3D image displayµ¥²¨³¤Ó°Ïñ¼°3DÁ¢ÌåͼÏñÏÔʾ

11. STDEV function±ê׼ƫ²î¼ÆËã·ÖÎö¹¦ÄÜ

12. All single spectral image save to PNGµ¥¹âÆ×Ó°Ïñ´¢´æ

13. Spectral binning function¹âÆ×·Ö±æÂʵ÷Õû¹¦ÄÜ

14. Spectral smoothing function¹âÆ×ƽ»¬ÐÞÕý¹¦ÄÜ

15. ²âÁ¿ÏµÍ³/Ó¦ÓÿØÖƼ°·ÖÎöÈí¼þ:

1) X1 Carbon 14" WQHD(2560x1440)IPS Screen£¬In i7-6500U£¬8GB RAM£¬512GB SSD

2£©¿Éµç¿ØÐýתƽ̨/ƽÐйâÔ´ÈëÉä½Ç/ƽÐйâÔ´µç¿ØÐýתÏßÆ«ÕñÆ÷/ÊÕ¹â½Ç¶È/ÊÕ¹âµç¿ØÐýתÏßÆ«ÕñÆ÷£»

3£©¿Éͼʾ: ÊÕ¹â½Ç¶È ¡¢ Æ«Õñ¡¢ Ïà¶ÔÇ¿¶È¡¢ ¹Ì¶¨ÈëÉä¹â½Ç¶È£»

    4£©¿Éͼʾ: Æ«Õñ¡¢ÏàŒ¦·´Éä¹âÆ×Ç¿¶È¡¢ ¹Ì¶¨ÈëÉä¹â½Ç¶È ¡¢ ÊÕ¹â½Ç¶È£»

Åä¼þ

1.  Reference panels£ºSpectralon®,10X10-inch(25.4X25.4cm), Calibrated, White, 99% Reflective/128170

2.  Rotary stage for AisaIBIS (for use in lab and ground applications) Ô­×°ÔÆ̨¼°Èí¼þ¿ØÖÆ

3.  Tripod for the ground useÔ­×°Èý½Å¼Ü

  1. ¿ìËÙ·þÎñ£¨´ÎÈÕµ½´ï£©

   2.Ãâ·ÑÌṩÊý¾Ý´¦ÀíÈí¼þÀ©Õ¹Ö§³ÖºÍ·þÎñ£¬°üÀ¨ÅäºÏ¾ßÌåÓ¦ÓÿªÕ¹¸ß¹âÆ׳ÉÏñÔ¶³Ì¿ØÖÆÄ£¿éµÄ±àд¡¢Êý¾Ý´¦ÀíµÈ¡£

²úÆ·×Éѯ

ÁôÑÔ¿ò

  • ²úÆ·£º

  • ÄúµÄµ¥Î»£º

  • ÄúµÄÐÕÃû£º

  • ÁªÏµµç»°£º

  • ³£ÓÃÓÊÏ䣺

  • Ê¡·Ý£º

  • ÏêϸµØÖ·£º

  • ²¹³ä˵Ã÷£º

  • ÑéÖ¤Â룺

    ÇëÊäÈë¼ÆËã½á¹û£¨Ìîд°¢À­²®Êý×Ö£©£¬È磺Èý¼ÓËÄ=7
΢ÐÅɨһɨ